<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-23 05-48-58
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 5/5, 73 dBuV P3 SR
Pilot RDS Phase Difference
6.5 kHz 3.4 kHz 77 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 27 kHz 16392 0,0061
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-5,5 dBr -2,93 dBr -1,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"P3 SR " E203 12 (Easy M) 0 1 1 9 12:21, 23.08.2025
RT
"Svenn med Isg & straund FliLisa Friberg "
AF EON
87.6, 87.9, 89.1, 90.7, 95.8, 97.2, 97.4, 97.9, 98.7, 99.0, 99.4, 100.5 MHz E201, E224, 5220, E402
FM Scope Max at: 27 kHz MIN: 10 kHz % above 76 kHz: 0,0061 Acquired: 2025/08/23 5.47.55 Total samples: 16392 Equivalent time: 0:13:39 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: -1,8 dBr MIN: -5,5 dBr AVE: -2,93 dBr % above 12,2 dBr: 0,0 Last value: -2,3 dBr (2025/08/23 5.47.54) 05.34 05.36 05.38 05.40 05.42 05.44 05.46 -6 -4 -2 0 Pm [dBr]